HDG100 Series Single Seat Regulating Valve
Technical Data and Features
Valve Body:
Type: Unbalanced
Nominal Diameter: 15~600mm(1/2" ~ 24")
Plug Type: Plunger
Flow Characteristics: Equal percentage, linear, Quick opening
Nominal Pressure: PN16 ~ 25MPa
ANSI Class 150LB ~ 1500LB;
Connection Type: Flange(RF、RTJ、FM)
Threaded
Welding(SW、BW)
Flange Standard: ASME B16.5
DIN EN 1092-1
GB/T 9113
HG/T 20615
HG/T 20592
Face to Face: ANSI/ ISA 75.03、ASME B16.10、DIN3202、GB/T 12221 etc.
Body and Bonnet Material: WCB、LCB、WC6、CF8M、CF3M、C12、ALLOY20、MONEL、Hastelloy C ,etc.
Trim Material: 316SS、316L SS、416SS、440C、
ALLOY20、MONEL、Hastelloy C,etc.
Above+R.TFE(Reinforced PTFE)
Above + Stellite (Hard faced)
Upper Bonnet Type: Standard type -29~250℃
High temperature extended type 250~565℃
Low temperature type -196~250℃
Steam jacket insulation type
Bellows seal type
Structure: Top-guided single-seat regulating valve
Packing: PTFE V-packing
Graphite packing etc.
Others: If the valve flash, it is recommended to choose a reduced-bore type, and the plug and seat are hard faced.
Actuator part:
| Item Type |
Pneumatic diaphragm type | Pneumatic piston type | Full electronic | Electric | Full electronic(temperature-regulated actuator |
| Task | Regulating/On-Off | Regulating/On-Off | Regulating | Switch | Regulating |
| Spring range | 20-100; 40-200;80-240KPa | - | - | - | - |
| Air source/power | 0.14,0.25,0.4MPa | 0.4~0.6MPa | 220V·AC50Hz | 220V·AC50Hz | 220V·AC50Hz |
| 380V·AC50Hz | 380V·AC50Hz | ||||
| Connector | Rc1/4”, Rc3/8” | Rc1/4”, Rc1/2”,Rc3/8” | Wiring: 2-G1/2” | Wiring: 2-G1/2” | M27x2 |
| (Temperature sensor connector) | |||||
| Connection type of action | Air open, air close | Air open,air close,double acting | Power on, power off | Power on, power off | Cooling control, heating control |
| Allowable ambient temperature | -40 ~ +80℃ | -60 ~ +65℃ | -10 ~ +50℃ | ||
| Optional valve accessories | Electric valve positioner, air filter regulator, solenoid valve, limit switch, lock-up valve, manual device | Overload unit | Inching switch for position detecting, potentiometer | - | |
The main technic data:
| Nominal diameter | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | ||
| Rated Kv | Linear | 6.9 | 11 | 17.6 | 27.5 | 44 | 69 | 110 | 176 | 275 | 440 | 690 | |
| Equal percentage | 6.3 | 10 | 16 | 25 | 40 | 63 | 100 | 160 | 250 | 400 | 630 | ||
| Rated stroke L(mm) | 16 | 25 | 40 | 60 | |||||||||
| Diaphragm effective area (pneumatic valve)Ae(cm²) | 280 | 400 | 600 | 1000 | |||||||||
| Inherent flow characteristics | Quick opening、linear、EQ% | ||||||||||||
| Inherent regulating ratio | 50:1 | ||||||||||||
| Allowable leakage | Hard seal: CLASS IV、CLASS V; Soft seal: CLASS VI | ||||||||||||